Notice: RS Serial: ID 0x43 is not used <-- can use for Aqualinkd (Extended Device ID) You are receiving this because you authored the thread.Reply to this email directly, view it on GitHub, or unsubscribe. I thought it was a capacitor read more CertifiedPoolPro Owner/Operator Pool Servi. sudo ./release/serial_logger /dev/ttyUSB0 -rsrd -d -p 5000000000 highlighing and pressing "select" on the PDA) the item "POOL MODE ON"? On 3/15/2009 at 11:08 PM, Pool Clown said: Unfortunately, your content contains terms that we do not allow. I can put in a lithium one in just to be sure. Please edit your content to remove the highlighted words below. Non power outage problems related to all pressure switches include corrosion of the contacts and fire ants getting into the contacts. Non-controllable AC pumps (most of them) are always operating at 100%. I have a Jandy RS-8 panel with a PDA (only), and a Jandy ePump (VSP). Inground, Fiberglass and Aboveground Swimming Pools, Aqualink Will Not Turn Off Pool Filter Pump, Clearwater Spa Monaco 3 / nothing working except the circulation pump, 2015 Hot Springs Grandee - No Power Issue. 11 root 20 0 0 0 0 I 0.0 0.0 0:00.00 rcu_bh A5 which is unused is 32v to relay when OFF. Jul 2 17:15:29 aqualinkd aqualinkd: Config override frz prot = NO Jul 2 17:16:25 aqualinkd aqualinkd: AUX ID Aux_5 has no control panel label using 'NONE' I also have a Jandy SpaLink RS. Does this sound like the right part - Jandy Aqua Link 3 hp. It could be okay. Follow along with the video below to see how to install our site as a web app on your home screen. The all connects just fine and things seem ok from there. Jul 2 17:15:29 aqualinkd aqualinkd: Debug RS485 protocol = YES (With AqualinkD not running obviously). If what AZM says don't work, then it's probably a stuck relay. (Easy Railing Replacement)https://youtu.be/jnpC1yAeR28What Are Creative Ideas for Pool Noodles? Thanks for your quick reply. Same problem. X LED will light when an auxiliary, assigned to light dimming, is turned on. Assume that the pump and all electronics are running correctly, and the Raspberry Pi running AqualinkD is unplugged from the power outlet (i.e. Hi, I run my pump 24/7 at a lower speed. CPU Voltage: 0.8625 Pool and spa lights heater, spa blower all trigger ok. Do you have a variable speed pump? But yeah, DC pumps are supposed to remember the last setting. extended_device_id_programming = no. There are some timing info in AqualinkD already, I'll start adding some more and think about how best to tackle this. Use the following To do that. If you can, store a few glow sticks near the pool to activate and toss to the bottom to help swimmers find their way to the stairs or ladder. Jul 2 17:15:29 aqualinkd aqualinkd: Config BTN Aux_5 = label NONE | This pump has continued to work for two seasons and still going strong and I was about to throw it away.If you really think that you need a new pool motor, then here is the link below to the one I bought recently once the motor in this video got too loud with screeching bearing noises and then finally froze up again. For a better experience, please enable JavaScript in your browser before proceeding. Jul 2 17:15:29 aqualinkd aqualinkd: Config BTN Spa_Mode = label Spa Mode | Learn more about our affiliate and product review process, Reset or Re Start Your Water Well After a Power Failure, By creating an account you agree to the Hunker, How to Wire Up a Well Water Pressure Switch. Hello , There was no answer in this thread for more than. NEVER remove the cover of the switch without turning off the breaker and letting anyone that may turn that breaker back on know what you are doing. The contactor only gives the pump power the control wire tell it to turn on. I'm getting the RS Serial: SERIOUS ERROR on RS485 sometimes every second and as long as 10 seconds before the next error. Nothing so far in the Web display, but every couple seconds I get the Error: RS Serial: SERIOUS ERROR on RS485, AqualinkD was too slow in replying to message! Jun-02-20 17:44:48 PM Debug: Kicking PDA thread 14,0x1fcf9e0 Thanks! I'm having some trouble with my installation and I'm not sure if you might have some insight. But with that interface board I assume its hard to get it wrong. 2 root 20 0 0 0 0 S 0.0 0.0 0:00.57 kthreadd Video of the Day Step 2 Scroll to and highlight "System Setup" using the arrow keys. The 2nd RS485 log does have the bad checksum error. Chlorine Tablets Floater Dispenserhttps://youtu.be/BExm78hRmWcWhat Are Dangerous Risks of Using Salt for an Above Ground Pool?https://youtu.be/PRFoTeW2KS8How to Replace a Pool Pump Motor? 0x11 is set % command, 0x41 is 65%. If it's a single speed, it could simply be the circuit breaker for the pump is off. 3 root 0 -20 0 0 0 I 0.0 0.0 0:00.00 rcu_gp No noise, no power - it seems like it's an electrical issue. Are they just standard 9vs? Still having to create chlorine by turning boost mode on. Ultimately RS-6 Combo and RS-2/6 Dual use the exact same key codes, so everything should work, just have a 1 more aux button that won't do anything for you. This just saved me from a week's worth of frustration. A loss of power may coincide with storms, high winds, heavy rains, floods, or earthquakes. Since AqualinkD was stopped I have no idea if I got the bad checksum error or not. Frequency Capped history : OK, top - 13:36:11 up 10 days, 20:20, 2 users, load average: 0.83, 0.73, 0.49 extended_device_id_programming = no Notice: RS Serial: ID 0x0a is not used <-- can use for Aqualinkd If something happens and it's too slow to reply, the panel will think it's replying to a different message, and makes everything go funky on you. I've been going down the path of trying to figure out where the BAD and UNKOWN packets were coming from. Next reset time and date, and functions. Thats where the filter pump relay is usually. Don't toss that pool pump motor until you try this simple trick to see if you can get it going again. http://www.poolspaforum.com/forum/index.ph=&pid=72514, The link you sent me was the exact same problem I'm having. About 100 bucks in nor-cal. Thanks for the clarification on the select line. My config file is attached. Jun 18 09:21:01 aqualinkd aqualinkd: Display warnings in web = NO Jul 2 17:15:29 aqualinkd aqualinkd: Config deamonize = YES Hello , This is an inactive thread. Aqualink is not sending any commands. Check the voltage on the secondary transformer (the two (2) outside yellow wires). When I try logging serial data, though, I don't see anything that appears to be odd, other than some "unknown" packets being sent to 0x78 (which I believe is my VSP): Jandy To 0x78 of type Unknown | HEX: 0x10|0x02|0x78|0x44|0x00|0x80|0x25|0x73|0x10|0x03|, Jandy To 0x78 of type Unknown | HEX: 0x10|0x02|0x78|0x41|0xcb|0x10|0x03|. With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. But it's the preceding 0x10|0x02|0x0c that's bad. Using your insulated pliers, in case of stray electrical current, lift the lever upward. So it is possible to hear a click but still no pump. Tried a poweedr USB hub, still had errors. when you open the web page to control the pool) aqualinkD shuts down my variable speed pump. Since I have a VSP, two things seem to have to happen to get the pump running. If so it could be that one of the 4 control wires to the pump is loose or not connected. Jul 2 17:15:29 aqualinkd aqualinkd: Config BTN Spa_Heater = label Spa Heater | MiB Swap: 100.0 total, 100.0 free, 0.0 used. Ive seen something very similar to this before, but Ill need some time to dig it up. It may not display this or other websites correctly. Subject: Re: [sfeakes/AqualinkD] AqualinkD turning VSP pump on/off repeatedly (. references Great forum, and I am happy to be a member. I was running AqualinkD on an PI 3B until 10 days ago when I switched to the 4B to see is system or network performance was a possible cause. Hallelujah! Jul 2 17:15:29 aqualinkd aqualinkd: Config idx SWG Percent = 0 2 root 20 0 0 0 0 S 0.0 0.0 0:00.56 kthreadd If it does find something, I'll give some nice big errors in the UI and also log them. The only unusual action around this time was I rebooted all my access points at about 2:05AM this morning which although is coincidental, I do not see how it can be related unless the iAqualink is is causing an issue when it is trying to re-connect. Jul 2 17:15:29 aqualinkd aqualinkd: Config serial_port = /dev/ttyUSB0 This will remain stable months, until for some random reason like this morning, everything seems to go out of sync again at about 2:14AM. Notice: RS Serial: ID 0x10 is in use <-- Pentair Master (Probably Jandy RS Control Panel) Then, I ordered a different RS-485 converter. With over 200,000 members, TFP is the largest and most influential pool & spa website on the Internet. Jul 2 17:15:29 aqualinkd aqualinkd: Config idx SWG PPM = 0 If you are on a water well and experience a power failure, the pressure switch may be of the type that has to be reset. This part of that message 0x10|0x02|0x50|0x11|0x41|0xb4|0x10|0x03| is the control panel telling the SWG to set to 65% (is 65% what your SWG is set to) ? If you have an account, sign in now to post with your account. pi@aqualinkd:~ $ sudo vcgencmd measure_volts sdram_p 4 root 0 -20 0 0 0 I 0.0 0.0 0:00.00 rcu_par_gp Here's the startup info: My friend, you got it. I tried scrolling from Auto to the service button, but the pump still stays on. All check out. This precaution will safeguard your pump, heater or. Not anymore, but I was wondering if I need to set them up for the pump to kick back on after a power outage of if there was a way to have it automatically turn on when it gets power back again. One other thing, if your PDA you may well be best using a version prior to V2.0 for the moment. It is being practiced by thousands of pool owners just like you. It got me thinking that if I am ever away from the house and we lose power, I would need to be aware and log back in and turn on the pump. Hope that works - there are a couple of other things it might be, but this is fairly common. Jun-02-20 17:44:48 PM Debug: PDA Menu Line 7 = SPA HEATER OFF Jun 18 09:21:01 aqualinkd aqualinkd: Config idx pool temp = -999 I twisted the pump wires and AqualLink together before connecting to the block so one would not slip while the other went in. Is there a way to turn on the pump automatically after a power outage besides setting a huge schedule every hour (or 30 min) to turn on the pump? Notice: RS Serial: ID 0x50 is in use <-- Salt Water Generator (Aquarite mode) Jun 18 09:21:01 aqualinkd aqualinkd: Config mqtt_dz_sub_topic = (null) ***> It should be here in a couple of days. If you lose power during the winter, those freezing temperatures could spell trouble for your pool. However, I have a problem with my pump. place to buy one, also are there instruction for installing it? 1759.2 avail Mem, PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND Jun 18 16:16:08 aqualinkd aqualinkd: BAD PACKET Jandy Packet | HEX: 0x10|0x02|0x39|0x10|0x02|0x20|0x02|0x00|0x00|0x00|0x00|0x00|0 I imagine it's common to have one slip out when you are dealing with tightening the others. Yup, thats it. Here's what I know, though. No change, the pump still shuts off over and over when connected to the RS-485 converter and Raspberry Pi. Electricity powers most these devices and is essential for your water quality and your safety. force_SWG = no Testing upload speed Page 15 Power Center Troubleshooting 4.2.1 Loss of Power Check the power center transformer for the proper voltage. It sounds like you have a RS485 termination issue that when you plug the pi in, its drawing more power and therefor taking something else off the buss. 9 root 20 0 0 0 0 S 0.0 0.0 0:03.94 ksoftirqd+. It will have wires coming out of it going to the pump and to the breaker box. You are using an out of date browser. Aqualink Problems - Lights Don't Work - Pool and Spa Forum The contactor only gives the pump power the control wire tell it to turn on. After compiling the new one I get: Notice: RS Serial: Jandy Control Panel Model : RS-2/6 Dual But one thing Id like to know, can you change the VSP rpm from the PDA? Notice: RS Serial: ID 0x33 is not used <-- can use for Aqualinkd (Prefered Extended Device ID) Remove the pool cover and check for debris. Give the walls and floor of your pool one round of circulation with a pool cleaner. I have an RS2/6 (dual equipment). 19049 root 20 0 0 0 0 I 0.3 0.0 0:00.06 kworker/u+ No When I turn my pump on - absolutely nothing happens. Jul 2 17:15:29 aqualinkd aqualinkd: Config mqtt_ID = aqualinkd_b827eb18 Throttled : OK You may not be through spending money. poolguy810 is online now Continue Related Pool and Spa Questions When I turn my pump on - absolutely nothing happens. You will get much more visibility by. All the pool equipment is very non specific as to whats terminated and what isnt, so kinda trial end error on specific versions of equipment as to how you can wire it, On Jun 2, 2020, at 9:55 PM, smurry ***@***. Jun 18 09:21:01 aqualinkd aqualinkd: Config device_id = 0x0a I enabled the serial_readahead config entry. I can code around the error, but I'd like to get to the root cause of it. This is a total guess on my part, but one possibility is that it is confusing my VSP for an aquapure system, and sending commands to what it thinks is the aquapure is actually going to my VSP and causing the on/off cycling. Jul 2 17:15:29 aqualinkd aqualinkd: Read Pentair Packets = YES Notice: RS Serial: ID 0x32 is not used <-- can use for Aqualinkd (Prefered Extended Device ID) If you have to clean these contacts, after disconnecting the power use spray contact cleaner and a small brass brush. Reset timers for your pump and any other device that is on a timer. You must log in or register to reply here. Jul 2 17:15:29 aqualinkd aqualinkd: Config PDA Mode = NO %Cpu(s): 6.8 us, 9.2 sy, 0.0 ni, 84.0 id, 0.0 wa, 0.0 hi, 0.0 si, 0.0 st Why Your Pool Pump Won't Turn On (And How To Fix It!) - Refresh Outdoors None of the breakers at the pump were tripped (the pump is set up in a small building with a large pentair control panel with extra breakers in thrre).) Open up the battery compartment and take a pencil eraser and clean the contacts. Your previous content has been restored. Jul 2 17:15:29 aqualinkd aqualinkd: Config extra_device_id = 0x41 The pump relay is working correctly and repeatably with AqualinkD. No. Its set as Error, (really should be notice or warning). It's almost like the pump needs a continuous string of "stay on" commands in order to stay running, which is very strange. In my power center I have a Jandy Surge protector which prevents surges on the RS 485 bus and that connects to the a Jandy expansion board. What happens is that when the pressure tank pressure falls below the low setting, usually between 20 and 35 psi, it causes the pressure switch to turn off. I am having an issue with my Aqualink RS not turning on the - JustAnswer Then, some command(s) over RS-485 to tell the pump to turn on and at what speed (and maybe other things as wellnot sure). Just a thought about this, not knowing exactly what this item in the log means. Jul 2 17:15:29 aqualinkd aqualinkd: Config socket_port = 80 DC pump settings after power outage | REEF2REEF Saltwater and Reef If you could download and run it, it'll check a few thinks on the Pi to see if there have been any system problems reported since last boot (like heat / power / voltage) that may cause a slowdown. pi@aqualinkd:~ $ sudo vcgencmd measure_volts sdram_c Right now I have a crontab that stops and starts aqualinkd at 20 past the hour so the SWG starts up again. x98|0x10|0x03| I'll post an update in a few hours, lets see what we can do about the "Too slow in replying" messages. Use a pole and a skimmer to remove anything that a suction cleaner cant handle. I am curious about the next part, though, specifically this: DA Menu '2' Selectedline 'POOL MODE ON', Last line received 'AIR POOL'. If AUX 1, 2, or 3<br /> were programmed to operate automatically, clear the programs before turning on the appropriate clip switch.<br /> One, the pump relay has to be turned on. (The expansion board has no terminators. Pentair Intelliflo dead after power outage? : r/swimmingpools - Reddit The power is finally back on. Very sorry for asking such a long an rambling question, but I hope you may have some insight. Installation and Operation Manual ePump Variable Speed Pump User Interface Jun 18 09:21:01 aqualinkd aqualinkd: Config override frz prot = NO It appears that the on/off cycling of the pump is related to the RS-485 bus. Maybe also use the raw reading of the USB port command listed in the wiki, see if that also messes with the pump. March 16, 2009 in All Swimming Pools Types. Generates chlorine fantastically, but have to manually turn it on and off at the panel by holding down the temperature button for ten seconds. I then set the config to "panel_type = RS-2/6 Dual" . Other times is when there is a Aqualink complete restart, about 50% of the time, the system will come back up and it seems like the iAqualink/AqualinkD is fighting or something. But one thing Id like to know, can you change the VSP rpm from the PDA? Could be microprocessor lockup - try turning off the power to the system (breaker) disconnect the battery, turn power back on then reconnect the battery. Sign in Removed all AqualinkD files on my system and installed the latest release. Here is an excerpt from the log file that covers one of these pump power-cycle events: As a final piece of information, if I wake up my PDA, everything returns to normal. First, I removed Aqualinkd from the system and reinstalled the latest 2.1.0. Undervolt history : OK Jun 18 09:21:01 aqualinkd aqualinkd: Config use_aux_labels = YES Anyway, I haven't reported back until now because I don't believe that the problem is related to AqualinkD, but I would greatly appreciate any insight that you might have. (Easy \u0026 Affordable)https://youtu.be/mJexau0Xt70Swimming Pool Lights Above Ground Pool Lights and Inground Pool Lightshttps://youtu.be/-VCSlQ0dJKcHow to Easily Get Steps Above Ground Pool Deck and Steps (On a Tight Budget)https://youtu.be/7Sj73wlO81sTop 5 Things You Need for Your Above Ground Swimming Poolhttps://youtu.be/d2aJH_jLA8EHow to Easily Put Chlorine in a Pool Like a Pro? How do I Reset a Jandy AquaLink System? | ehow 0x50 is SWG. Is this the right part - Jandy Aqua Link 3 hp. (please check OS for performance issues). Jun 18 14:16:08 aqualinkd aqualinkd: Serial read bad Jandy checksum, ignoring Before describing my issue, I want to thank you for what has to have been an incredible amount of time spent on this project. Using our free app for your smart phone or web-connected device, you can control all the elements of your pool or pool/spa system, even when you're on the go Please consider. Jun 18 09:21:01 aqualinkd aqualinkd: Config PDA Sleep Mode = NO Can you please describe every device you have wired up to the RS485 bus and how / where it's wired? turned off). Jul 2 17:15:29 aqualinkd aqualinkd: Starting web server on port 80 My Jandy Aqualink won't power up, What can I do? To my - JustAnswer bfrench Jul 2 17:15:29 aqualinkd aqualinkd: Config mqtt_aq_topic = aqualinkd Maybe also use the raw reading of the USB port command listed in the wiki, see if that also messes with the pump. Installed iAquaLink - pump won't turn on - [STAGING] Trouble Free Pool Tried to set it to 0 and didn't notice any difference in error timing but CPU usage went up to 60-70%. You don't have to program the iAqualink it is just an input/output for the panel, the panel is still in control. Ok, but if I lose power at say 9am, would I be waiting 23 hours before it kicks back on or will it see it is in a schedule block and fire right back up as soon as power is restored? Jun 18 09:21:01 aqualinkd aqualinkd: Starting web server on port 80